Send Message
Home ProductsOverhead Insulated Cable

Insulated Overhead Conductor Cables , 120mm2 Soft Copper Overhead Cable

Insulated Overhead Conductor Cables , 120mm2 Soft Copper Overhead Cable

Insulated Overhead Conductor Cables , 120mm2 Soft Copper Overhead Cable
  • Insulated Overhead Conductor Cables , 120mm2 Soft Copper Overhead Cable
  • Insulated Overhead Conductor Cables , 120mm2 Soft Copper Overhead Cable
  • Insulated Overhead Conductor Cables , 120mm2 Soft Copper Overhead Cable
  • Insulated Overhead Conductor Cables , 120mm2 Soft Copper Overhead Cable
  • Insulated Overhead Conductor Cables , 120mm2 Soft Copper Overhead Cable
Product Details:
Place of Origin: Wuhan, China
Brand Name: Green Song
Certification: IEC, ASTM,BS,NF,VDE,NZS,ANSI ,DIN JES,JEC(CSA).
Model Number: Low voltage
Payment & Shipping Terms:
Minimum Order Quantity: 500m
Price: Negotiable
Packaging Details: wooden drum/wooden-steel drum/steel drum/wooden carton or as customer request
Delivery Time: As customer request
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now
Detailed Product Description
High Light:

Insulated Overhead Conductor Cables

,

Overhead Conductor Cables 120mm2

,

Soft Copper Overhead Cable

  • XLPE insulated overhead insulated cable 1k V
  • Application

This product is suitable for overhead power lines with AC rated voltage of 10kV and below.

  • Cable Performance

The long-term allowable operating temperature of the cable shall not exceed 90℃.

Cable bending radius: cable outer diameter (D) less than 25mm, shall not be less than 4D; cable outer diameter (D) greater than 25mm, shall not be less than 6D.

  • See Table 1 for the cable model and name

Table 1

model name
JKYJ Copper-core xLPE insulated overhead insulated cable
JKTRYJ Soft copper core xLPE insulated overhead insulated cable
JKLYJ Aluminum coreXLPE insulated overhead insulated cable
  • The structure and technical parameters of 1kV overhead insulated cable are shown in Table 2 and Table 3

 

Table 2, JKYJ 1kV JKTRYJ 1kV

nominal cross

(mm2)

The minimum number of conductors Outer diameter of the conductor (reference value)

Insulation nominal thickness

(mm)

Average cable D maximum (mm)

20℃ conductor DC resistance

Not over (Ω / km)

90℃ Minimum insulation resistance

(MΩ •km)

Cable pull-off force

N

Hard copper core Soft copper core Hard copper core
10 6 3.8 1.0 6.5 1.906 1.83 0.67 3471
16 6 4.8 1.2 8.0 1.198 1.15 0.65 5486
25 6 6.0 1.2 9.4 0.749 0.727 0.54 8465
35 6 7.0 1.4 11.0 0.540 0.524 0.54 11731
50 6 8.4 1.4 12.3 0.399 0.387 0.46 16502
70 12 10.0 1.4 14.1 0.276 0.268 0.40 23461
95 15 11.6 1.6 16.5 0.199 0.193 0.39 31759
120 18 13.0 1.6 18.1 0.158 0.153 0.35 39911
150 18 14.6 1.8 20.2 0.128 0.124 0.35 49505
185 30 16.2 2.0 22.5 0.1021 0.0991 0.35 61846
240 34 18.4 2.2 25.6 0.0777 0.0754 0.34 79823

 

Table 3, JKLYJ 1kV

nominal cross

(mm2)

The minimum number of conductors Outer diameter of the conductor (reference value)

Insulation nominal thickness

(mm)

Average cable D maximum (mm)

20℃ conductor DC resistance

Not over

(Ω/km)

90℃ Minimum insulation resistance

(MΩ •km)

Cable pull-off force

N

10 6 3.8 1.0 6.5 3.08 0.67 1650
16 6 4.8 1.2 8.0 1.91 0.65 2517
25 6 6.0 1.2 9.4 1.20 0.54 3762
35 6 7.0 1.4 11.0 0.868 0.54 5177
50 6 8.4 1.4 12.3 0.641 0.46 7011
70 12 10.0 1.4 14.1 0.443 0.40 10354
95 15 11.6 1.6 16.5 0.320 0.39 13727
120 15 13.0 1.6 18.1 0.253 0.35 17339
150 15 14.6 1.8 20.2 0.206 0.35 21033
185 30 16.2 2.0 22.5 0.164 0.35 26732
240 30 18.4 2.2 25.6 0.125 0.34 34679
300 30 20.6 2.2 27.2 0.100 0.33 43349
400 53 23.2 2.2 30.7 0.0778 0.32 55707

 